Standards & Labeling

Table of Contents

The Energy Conservation Act, 2001 gives the power to central government, who in consultation with BEE may:

Standards and Labeling has been identified as one of the key activities for energy efficiency improvements, for:

S&L programs impact the energy savings in the medium and long run, as most of the equipment and appliances that will account for building energy use, say 20 years from now, have not yet been manufactured.

Impact on Refrigerators: US Example

In India, the labeling program under BEE has been launched. The star rating ranges from 1 to 5 in the increasing order of energy efficiency and gives choice to consumer for choosing equipment or appliance. A typical comparative label is:

Overview of the Labeling Process

  1. Identify and prioritize products for labeling;
  2. Set up Steering Committee including all stakeholders;
  3. Identify critical issues and organize technical subcommittees;
  4. Finalize test procedures, lab specifications, minimum technical qualifications;
  5. Assess market and product characteristics w.r.t. energy efficiency;
  6. Develop technical criteria for labeling;
  7. Develop implementation and enforcement plan;
  8. Notification after finalizing all the technical and admin details;
  9. Launch labels;
  10. Consumer awareness campaign;
  11. Check and challenge testing; and
  12. Program monitoring, review, and updates.

Criteria for selecting products for labeling: Select products that:

  • that use a significant amount of energy;
  • that are present in most households or where rapid growth is predicted;
  • for which energy-efficient technology exists but is not being used in most products in the market; and
  • for which there is a significant variation in the energy efficiency of different units.

Establishment of a rating plan:

  • Compile data on energy consumption of Indian equipment and benchmark against international ones.
  • Comparison to be on an equitable terms, taking into account variations in test procedures, product design, and other considerations.
  • Target of the programme is to achieve highest international efficiency levels for that category.
  • Highest efficiency may be achieved gradually.
  • Recommend time for achieving highest efficiency.
  • Rating plan to be reviewed periodically.

Scheme for Energy Efficiency Labeling

The scheme has been developed in collaboration with all stakeholders, and aims at providing information on energy performance so that consumers can make informed decisions while purchasing appliances.

The scheme was launched in May, 2006.

Scope

The scheme is currently applicable for following appliances. Mandatory labeling for first 4 was notified from January 7, 2010.

Mandatory Schemes:

  1. Frost Free (No-Frost) Refrigerator
  2. Tubular Fluorescent Lamps
  3. Room Air Conditioner
  4. Distribution Transformer

Voluntary Schemes:

  1. Room Air conditioners (Cassette, Floor Standing Tower, Ceiling, Corner AC)
  2. Direct Cool Refrigerator
  3. Induction Motor
  4. Agricultural Pump Set
  5. Ceiling Fan
  6. LPG Stoves: currently under abeyance
  7. Electric Geyser
  8. Color TV
  9. Washing Machine
  10. Computer (Notebook / Laptop)
  11. Ballast (Electronic / Magnetic)

Scheme Implementation

The test procedures, schedule of tests, rating plan, sampling plan, qualification requirements, label design, label fee and the manner of display of label in relation to equipment have been specified in the schedule of particular appliance.

Label design and display:

  • The label design specifies the orientation, spacing, type, size, type faces, line width, security features, and any other feature required to clearly display the required information.
  • The label so designed shall include security features like holographic, or unique serial number, or bar codes, etc.
  • The label contents shall contain energy consumption or energy efficiency of the equipment and other equipment specific information

The National Standards and Labeling Implementation Committee will be set up by BEE to oversee implementation of scheme. The committee will be chaired by DG, BEE and consists of representatives from Ministry of Power, BIS, consumer associations, manufacturer associations and test laboratories.

The committee will recommend BEE on:

  • Enforcement of provisions of this scheme.
  • Develop the criterion for deciding whether challenge test and further action should be taken.
  • Verification of the legitimacy of challenges to the label.
  • Selection of samples for verification and challenge testing.
  • Any such issue as are considered crucial to the implementation of scheme.

Scheme Participation Process

Before application, applicant should check the energy labeling requirement for the respective equipment as per schedule. The Schedule conditions shall be complied for the respective product before participating in the S&L Program.

Application and grant of authority to affix labels:

  • Registration of the company/equipment with BEE.
  • Registration with BEE for the particular model.
  • Agreement with BEE valid for a period of 3 years.
  • Application along with registration and labeling fee, test report of the model and sample label. Rated values must be declared in test report.
  • The BEE to scrutinize application and seek further information, if required.
  • Issuance of authorization of label by BEE through E-mail/Letter.
  • The user of label to print and affix the label as per prescribed design, manner of display and rating plan.
  • BEE to prepare poster/brochure informing consumers how to interpret label and select equipment. The user of label to distribute copy of the poster/brochure with their technical brochure and also display at point of purchase.
  • The user of label to maintain the list of labeled equipment and submit to BEE every six months.
  • A list of labeled equipment and information on the label will be maintained by BEE and will be made available to public through publication and on its website,
  • The user of label shall be solely responsible for ensuring:

    • for the accuracy of the information displayed on the label;
    • use of label only for equipment/models for which agreement is made.

Consumer awareness:

  • BEE will work towards creating a larger market for energy efficient equipment through consumer awareness and consumer education.

Program evaluation:

  • BEE will appoint an independent agency to evaluate the program impact and process of implementation on a periodic basis. The scope of evaluation will include the impact on sales, energy consumption, cost, consumer purchasing behavior, manufacturing, national energy use and environment.
  • BEE will review the scheme periodically to determine the need for revision or amendment or termination of the scheme.

Label Verification Process

  • The BEE will verify the label content, and the manner of display of label for each equipment / model on a regular basis.
  • Verification testing will be conducted in an independent laboratory registered with BEE.

Challenge Testing

  • The label content can be challenged by any person by submitting the challenge to BEE in writing.
  • The Committee will recommend whether to conduct a challenge test, keeping in view the basis of the complaint and examination of past records.
  • The decision of BEE whether to conduct the challenge testing will be final.
  • Verification testing will be conducted in an independent laboratory registered with BEE.
  • If the equipment fails the challenge testing, the enforcement process will be followed.

Enforcement Process

  • If the equipment fails the verification / challenge testing, then the matter will be placed before the Committee and user of the label will be informed about the failure.
  • The user of the label has the option to go in for second test.
  • If the equipment passes the second test, then no further action would be taken and equipment would deem to confirm to label.
  • If the equipment fails the second test, then the user of the label will:

    • correct the label or remove the defect / discrepancies for new equipment yet to be shipped;
    • change particulars / information on advertising material.
  • If the user of label fails to comply with the direction issued after failure in second test, then:

    • Use of label for that model will be prohibited.
    • BEE will inform the consumers about the failures of the equipment/model by wide publicity.
    • BEE may advise the government to debar the equipment/model and/or the user of label from participating in any public tender.

Registration of Independent Testing Labs

  • An independent laboratory with a valid accreditation from NABL or other international accreditation in force (with NABL approval) for the test procedures (energy efficiency and other performance tests) can register with BEE.
  • The laboratories may be reviewed initially during registration and then on a regular basis, and in case any laboratory ceases to fulfill any condition laid down at the time of registration, registration will be withdrawn.
  • If the test results of a particular lab are consistently found to be incorrect, then registration of the lab will be withdrawn, and wide publicity will be given of disqualification.

Star rating of appliances

The following sections tabulates star rating criterion for appliances as per BEE schedule for respective appliance:

Tubular Fluorescent Lamps

Applicable to 4 feet tubular fluorescent lamps up to 40 W for general lighting service, colour temperature 6500 K for halo-phosphates and 6500 K, 4000 K, & 2700 K for tri-phosphate category. Referred IS are IS 2418, Part-I and Part-II.

Star rating for tubular fluorescent lamps
Star rating1☆2☆3☆4☆5☆
lm/W at 0100 hours of use<61≥61 & <67≥67 & <86≥ 86 & <92≥92
lm/W at 2000 hours of use<52≥52 & <57≥57 & <77≥77 & <83≥83
lm/W at 3500 hours of use<49≥49 & <54≥54 & <73≥73 & <78≥78
Under test conditions, when in tested in accordance with IS 2418. Actual efficiency will vary as per site conditions.

Room Air-conditioners

Applicable to single-phase split and unitary air conditioners of the vapour compression type, for household use up to a rated cooling capacity of 11 kW and that fall within the scope of IS:1391 Part-1 and Part-2, being manufactured, imported, or sold in India.

Star rating for room air-conditioners

Valid from 01/01/2007 to 31/12/2007
 EER (W/W)
Star ratingMinMax
1☆2.302.49
2☆2.502.69
3☆2.702.89
4☆2.903.09
5☆3.10 
Valid from 01/01/2008 to 31/12/2009
 EER (W/W)
Star ratingMinMax
1☆2.502.69
2☆2.702.89
3☆2.903.09
4☆3.103.29
5☆3.30 
Valid from 01/01/2010 to 31/12/2012
 EER (W/W)
Star ratingMinMax
1☆2.702.89
2☆2.903.09
3☆3.103.29
4☆3.303.49
5☆3.50 
Valid for unitary AC from 01/01/2012 to 31/12/2013
 EER (W/W)
Star ratingMinMax
1☆2.302.49
2☆2.502.69
3☆2.702.89
4☆2.903.09
5☆3.10 
Valid for unitary AC from 01/01/2014 to 31/12/2015 &
Valid for split AC from 01/01/2012 to 31/12/2013
 EER (W/W)
Star ratingMinMax
1☆2.502.69
2☆2.702.89
3☆2.903.09
4☆3.103.29
5☆3.30 
Valid for split AC from 01/01/2014 to 31/12/2015
 EER (W/W)
Star ratingMinMax
1☆2.702.89
2☆2.903.09
3☆3.103.29
4☆3.303.49
5☆3.50 

BEE has also specified voluntary schemes for cassette type, floor standing type, ceiling / floor type, and corner AC units. The star rating for these units is same as that of split type AC given in tables above.

Distribution Transformer

Applicable to oil immersed, naturally air cooled, three phase, and double wound non-sealed type out-door distribution transformer. The standard rating covered is 16, 25, 63, 100, 160, and 200 kVA and non-standard ratings from 16 kVA to 200 kVA.

Star rating for distribution transformers
kVA Rating1☆2☆3☆4☆5☆
Max losses at 50 % (W)Max losses at 100 % (W)Max losses at 50 % (W)Max losses at 100 % (W)Max losses at 50 % (W)Max losses at 100 % (W)Max losses at 50 % (W)Max losses at 100 % (W)Max losses at 50% (W)Max losses at 100 % (W)
16200555165520150480135440120400
25290785235740210695190635175595
6349014154301335380125034011403001050
10070020206101910520180047516504351500
160100028008802550770220067019505701700
2001130330010103000890270078023006702100

For non-standard ratings between 16 to 200 kVA, the applicable losses at corresponding loading shall be determined by adding pro-rata difference of loss to the loss of the nearest lower capacity transformer losses, i.e.

LossNS = (KVANS - KVASL) / (KVASH - KVASL) x (LossSH - LossSL) + LossSL;

where NS is non-standard, SL and SH are for standard capacities just below and above the non-standard rating.

Frost free (no-frost) refrigerators

Applicable to electric mains powered frost free refrigerating appliance of the vapour compression type intended for household and similar use being manufactures, imported, or sold in India.

Star rating for frost free refrigerators

Valid from 07/01/2010 to 31/12/2011
 CEC (kW⋅h/year)
Star ratingMaxMin
1☆≤0.8716*Vadj+7590.6973*Vadj+607
2☆≤0.6973*Vadj+6070.5578*Vadj+486
3☆≤0.5578*Vadj+4860.4463*Vadj+389
4☆≤0.4463*Vadj+3890.3570*Vadj+311
5☆≤0.3570*Vadj+311 
Valid from 01/01/2012 to 31/12/2013
 CEC (kW⋅h/year)
Star ratingMaxMin
1☆≤0.6973*Vadj+6070.5578*Vadj+486
2☆≤0.5578*Vadj+4860.4463*Vadj+389
3☆≤0.4463*Vadj+3890.3570*Vadj+311
4☆≤0.3570*Vadj+3110.2856*Vadj+249
5☆≤0.2856*Vadj+249 
Valid from 01/01/2014 to 31/12/2015
 CEC (kW⋅h/year)
Star ratingMaxMin
1☆≤0.4463*Vadj+3890.3570*Vadj+311
2☆≤0.3570*Vadj+3110.2856*Vadj+249
3☆≤0.2856*Vadj+2490.2285*Vadj+199
4☆≤0.2285*Vadj+1990.1828*Vadj+159
5☆≤0.1828*Vadj+159 
Where:
  • CEC (Comparative Energy Consumption): It is the nominal energy consumption of the model and is based on PAECav. It appears on the label.

    CEC = K * Vadj + C (kW⋅h/year)

  • K is constant multiplier (kW⋅h/litre/year)
  • C is constant fixed allowance (kW⋅h/year)
  • Vadj (Total Adjusted Storage Volume): The rated storage volume of a compartment of fridge adjusted to compensate for heat loadings if its temperature is different from fresh food compartment viz freezer.

    So, Vadj = fresh food compartment volume + Adjusted Volume Factor * target compartment volume + ... (litre)

    Adjusted Volume Factor = (test room temperature - target compartment temperature) / (test room temperature - fresh food compartment temperature)

  • Tested Energy Consumption (Et): The value of energy consumed in as determined by IS 15750 : 2006 for a period of 24 hours.
  • Projected Annual Energy Consumption (PAEC): The estimated annual energy consumption.

    PAEC = Et * 365 / 1000 (kW⋅h/year)

Direct cool refrigerators

Applicable to electric mains powered direct cool refrigerating appliance of the vapour compression type intended for household and similar use being manufactures, imported, or sold in India.

Star rating for direct cool refrigerators

Valid from 01/11/2006 to 31/12/2011
 CEC (kW⋅h/year)
Star ratingMaxMin
1☆≤0.645*Vadj+5410.516*Vadj+432
2☆≤0.516*Vadj+4320.413*Vadj+346
3☆≤0.413*Vadj+3460.330*Vadj+277
4☆≤0.330*Vadj+2770.264*Vadj+221
5☆≤0.264*Vadj+221 
Valid from 01/01/2012 to 31/12/2013
 CEC (kW⋅h/year)
Star ratingMaxMin
1☆≤0.413*Vadj+3460.330*Vadj+277
2☆≤0.330*Vadj+2770.264*Vadj+221
3☆≤0.264*Vadj+2210.211*Vadj+177
4☆≤0.211*Vadj+1770.169*Vadj+141
5☆≤0.169*Vadj+141 
Valid from 01/01/2014 to 31/12/2015
 CEC (kW⋅h/year)
Star ratingMaxMin
1☆≤0.330*Vadj+2770.264*Vadj+221
2☆≤0.264*Vadj+2210.211*Vadj+177
3☆≤0.211*Vadj+1770.169*Vadj+141
4☆≤0.169*Vadj+1410.108*Vadj+91
5☆≤0.108*Vadj+91 

All symbols have the same meaning as that for frost-free refrigerator, except Tested Energy Consumption (Et) is as determined by AS/NZS 4474.1 : 1997 and target temperature of freezer compartment is taken as -6 °C.

Induction Motors

Applicable for 3-phase squirrel cage induction motor for continuous duty operation of ratings from 0.37 kW to 375 kW and conforming to minimum performance requirements of IS 12615 : 2011.

The star rating plan shall be as per the following table:

Star rating of Induction Motors
Star ratingMoror efficiency class
1☆≥ IE2 & < IE2(+)
2☆≥ IE2(+) & < IE3
3☆≥ IE3 & < IE3(+)
4☆≥ IE3(+) & < IE3(++)
5☆> IE3(++)

IE2 and IE3 values are based on IS 12615 : 2011. IE3(++) is equivalent to IE4. The (+) values are higher than corresponding base value, but lower than next base value. IE2 value is the minimum entry level for labelling as per this scheme.

Comments

Post a comment